FAQ
   
 
 
Personal Control Panel
Your status is : Guest Login  Register

 
Back Reply New Topic    
Topic£ºStart P05 Alert (KDE6700)
  Author£ºmaple¡¡ 2009-10-12 12:22:27¡¡¡¡ Reply
I have KDE6700 with ATS, My generator was not detecting electricity from the main supply so whenever i put it on autostart it starts running itself. In order to further investigate the problem i turn it to manual, self the ignition and then hit the switch button. It worked find but then i tuned it off and press the scan button and after than it starts showing this error "Start P05" . Now its not starting at all. Any idea how i find out the fault? i called the agent and the serviceman they sent didnt know shit.
reply£ºStart P05 Alert (KD
firstly drop the control panel forward and behind the digital display there is a ribbon cable. Make sure this is correctly clipped into the back of the digital panel. Does the machine start in manual when you turn the key? There is a fuse in a white clip over holder hidden in the wiring loom. Sometimes this is seen looking behind the control panel some times its easier to remove the whole end panel where the air filter is to make access easier. you need to check this fuse. Really I need to know whether it starts off the key. let me know. we CAN sort this